Integrator control block with a positive time constant T

control block
integrator
Author

Mathilde Bongrain

Published

April 10, 2024

Diagram

integrator diagram

Integrator control block with a positive time constant T diagram

Syntax:

  • function name: int
  • input variable : \(x_i\)
  • output variable : \(x_j\)
  • data name, parameter name or math expression for \(T\)

Internal states : none

Discrete variable : none

Equations

\[ T \dot{x_j} = x_i\]

N.B. A zero value for \(T\) is not allowed. If too small a value is specified for \(T\), the solver may encounter a singularity and the simulation may not proceed.